Top Loading Swiftlock Options |
AAP800 |
Multi Program Controller (SecureTouch)
This option adds an additional 5 programs, giving 10 programs in total
which can be set by the user to save and store cycle parameters for
repeated use. The saved programs can then be selected via the touch
screen controller. |
AAR100 |
Integral Data Printer
The Integral Data Printer is essential where a traceable cycle record is
required, it records temperature and elapsed time for each cycle, together
with cycle stage messages and time of cycle. The printer employs a long
life ink ribbon system which provides fade resistant printouts. |
AJP150 |
External Vessel Heating - Vacuum models only |
AAR500 |
Sterilization Datalogger
Fascia or stand-alone datalogger for the recording and storage
of cycle data |
AAN014 |
Load Sensed Process Timing
This option allows the cycle timing to be controlled via the temperature
achieved in the centre of the load. A wandering probe situated within
the chamber is inserted into the load, or a load simulator, and initiates
the sterilization period once the probe reaches the sterilization
temperature. A Selectable ‘profiled overshoot boost’ feature speeds
up the cycle and minimizes over-processing of media loads. |
AAR120 |
RS232 Interface
This allows cycle progress to be monitored on an external computer
equipped with suitable software (Computer not supplied). Windows
itself provides a suitable interface, and any spreadsheet may be used
to view the data. |
AAR122 |
Ethernet Interface
Ethernet connectivity for a variety of applications. |
AAN009 |
Pulsar© Freesteaming PAT
Non vacuum units only. Selected via the Secure controller, this feature
assists with air removal from ‘difficult’ loads. The cyclical opening and
closing of the vent valve greatly increases turbulence at the
Freesteaming stage. |
AAP019 |
AutoFill - Automatic Mains Supply Waterfill
The Autofill option automatically maintains adequate water level within
the chamber. This is a fully automatic system incorporating an internal
reservoir tank which accepts mains cold water at 2-6 bar pressure. The
water inlet is controlled by level switching and includes an air gap to
comply fully with EC water regulations. The unit is readily connected to the
water supply via a 1.5m flexible hose (supplied). All units supplied with the
Vacuum Option or Deluge cooling have Waterfill supplied as standard |
AAP006 |
Assisted Air Cooling
Powerful fans are built within the cabinet outside the chamber, these
circulate ambient air over the external chamber walls, and result in an
appreciable reduction in cycle times. |
AAP080 |
Advanced Water Cooling
This can only be fitted to machines that have been connected to a
mains water supply. A series of cooling coils are fitted to the outside of
the autoclave chamber. At the end of the cycle these coils are circulated
with cold water, resulting in a rapid decrease of temperature. NB Please
note that all vacuum Square Section Sterilizers are fitted as standard with
water cooling ( where applicable). |
AVC005 |
Option for Category III Compliance - Vaccum Models
Steam enters the chamber through the chamber drain which is sealed
during the cycle ensuring all condensate is sterilized. A Bacterial
retentive filter fitted into the exhaust line ensures that nothing leaves
the chamber without being sterilized. The positioning of the filter
ensures that it is sterilized during every cycle. |
AVC100 |
Exhaust Heat Exchange System
An option to significantly reduce the temperature of the exhaust/waste
in situations where heat resistant drains are not present. N.B This option
requires a mains water supply. (Supplied as standard on Vacuum units) |
AAN036 |
Stainless Steel Wire Basket 400 dia x 400 h |
 |
AAN042 |
Stainless Steel Wire Basket 400 dia x 230 h |
AAN056 |
Morrison Discard Container 390 dia x 500 h |
 |
AAN058 |
Morrison Discard Container 390 dia x 355 h |
AAN002 |
Load Support Plate |
|