Square Section Options |
AAQ102/AAQ302 |
Full Heated Jacket
This option provides a full pressurized jacket around the chamber
and further enhances the drying performance of the sterilizer. In
conjunction with the vacuum option this is the most effective way of
drying loads and is essential for fabric loads and wrapped instruments. |
AVQ004 |
Air Ballast
For use on vacuum units only, unless external air ballast is available. This
option provides a controlled replacement of steam with compressed air
during the cooling phase. This effectively prevents the ‘boiling over’ of
bottled fluids that is frequently associated with assisted cooling systems. |
AAQ014 |
Load Sensed Process Timing
This option allows the cycle timing to be controlled via the temperature
achieved in the centre of the load. A wandering probe situated within
the chamber is inserted into the load, or a load simulator, and initiates
the sterilization period once the probe reaches the sterilization
temperature. A Selectable ‘profiled overshoot boost’ feature speeds
up the cycle and minimizes over-processing of media loads. |
| AAQ503 |
Integral Air Compressor
A supply of compressed air is necessary on all units fitted with either
the Logi Touch Screen Controller, or the Automatic Door system. The
Air supply is required to operate the pneumatic door system and/or the
pneumatic valves used in conjunction with the touch screen controller.
This option is therefore essential where such a supply is not available |
AVQ007 |
SPF Seal
A bacteriological seal mounted on a special flange to enable a double
doored unit to be installed between a sterile and a non sterile area. The
SPF seal/flange is fitted against the dividing wall and prevents bacterial
migration between the areas |
AVQ005 |
Option for Category III Compliance - Vaccum Models
Steam enters the chamber through the chamber drain which is sealed
during the cycle ensuring all condensate is sterilized. A Bacterial
retentive filter fitted into the exhaust line ensures that nothing leaves
the chamber without being sterilized. The positioning of the filter
ensures that it is sterilized during every cycle. |
AAQ100 |
Integral Data Printer
The Integral Data Printer is essential where a traceable cycle record is
required, it records temperature and elapsed time for each cycle, together
with cycle stage messages and time of cycle. The printer employs a long
life ink ribbon system which provides fade resistant printouts. |
AAR500 |
Sterilization Datalogger
Fascia or stand-alone datalogger for the recording and storage
of cycle data |
AAQ120 |
RS232 Interface
This allows cycle progress to be monitored on an external computer
equipped with suitable software (Computer not supplied). Windows
itself provides a suitable interface, and any spreadsheet may be used
to view the data. |
AAR122 |
Ethernet Interface
Ethernet connectivity for a variety of applications. |
AJA100 |
Deluge Cooling
A super-quick internal spray-cooling system for use only in conjunction
with sealed fluid loads (e.g. bottled media). This option can result in
up to a 50% reduction in cooling time for specialised fluid applications. |
AAP006 |
Assisted Air Cooling
(Non Vacuum models only)Powerful fans are built within the cabinet outside the chamber, these
circulate ambient air over the external chamber walls, and result in an
appreciable reduction in cycle times. |
AJA102 |
Internal Circulation Fan Cooling
Fan(s) are sited within the chamber itself, which create turbulence
reducing cooling time greatly. Internal fan cooling in conjunction with
advanced water cooling system is one of the most efficient ways of
reducing cycle times on fluid loads. |
SPL285 |
Blow Down Vessel
Required on models with Steam Generators, where there is not the
facility to accept Blow Down of up to 6bar. This option allows the steam
generator to be blown down at high pressure by a competent person.
The contents of the Steam Generator are blown into this specially
designed vessel. The regular action of blow-down reduces the build
up of limescale and other particulate matter, elongating the life span
of the generator and it's heaters. |
AAW001/AAW002 |
Water Softener
Water Softener - Single Unit Recommended to reduce the build up of
limescale on heaters, pipework etc, and particularly recommended for
units with steam generators. OR unit including a separate brine tank,
allowing installation in difficult or restricted positions. Requires salt.
(Full details, including service requirements, available upon request) |
| AAQ300 |
Discard Container 300 x 300 x 300mm |
 |
| AAQ801 |
Additional Shelf & Runner |
| AAQ600 |
Loading System - 1 External Trolley & 1 Internal Truck |
| AAQ602 |
Loading System - 2 External Trolleys & 1 Internal Truck |