Square Section
- Automatic Vertical Door - Vacuum |

Please
click here
for the full range of options and Accessories.
 |
High Standard Specifications
- 125 to 1000 litres (plus)
Suitable for a wide range of
applications including: Fabrics,
Porous Loads, Media, Discard, Waste, CAT III Applications etc. (NB
- Certain applications may require additional options) |
|
Included as standard:
- Ped
compliant 316 Stainless Steel Pressure Vessel
- Logi
Touch Screen Controller - Multi Cycle
- Integral Steam
Generator (unless otherwise specified) 18/24/36/48kW
- Single or Double
Door
- Automatic Door/s
- Horizontally sliding
- Vacuum System
- Liquid Ring
- Jacketed Water
Cooling
- Data Archiving
- Exhaust Heat
Exchanger
- Base Tray
|
Additional Options
/ Accessories: |
- Air Ballast (Integral/External)
- CAT III Compliance
/Effluent Retention
- Full Heated /
Cooling Jackets
- Data Recording
Devices
- Shelving &
Loading Systems
- Load Sense Process
Timing
- External Steam
Generator eg. 72kW
|
|
|
Astell have many years experience
in manufacturing Square Section units and can offer:
- Bespoke Units
- Special Vessel
Sizes
- Full Sterilizer
Suite Installations
- Units of 1000
litres plus
Please click Email
to Request Quotation for either
our standard units listed below, or for a unit to match your precise
requirements |
|
Reference
|
Vacuum |
Door/s |
Heating
Type |
Power
Supply Phase Amps/Phase kW Total |
Chamber
Litres |
Internal
Chamber Dims w x h x d |
Overall
Dims w x h x d |
|
NB
- These are typical examples - Astell can manufacture almost
any configuration - please contact us with details |
|
AVS125G |
Yes |
1 Auto |
Integral Generator |
3 ph Neutral-38A
28 kW* |
125 |
500 x 500 x
500 |
1100 x 2000
x 1300 |
|
AVS125D |
Yes |
1 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
125 |
500 x 500 x
500 |
1100 x 2000
x 1300 |
|
AVS216G |
Yes |
1 Auto |
Integral Generator |
3 ph Neutral-38A
28 kW* |
216 |
600 x 600 x
600 |
1250 x 2000
x 1400 |
|
AVS216D |
Yes |
1 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
216 |
600 x 600 x
600 |
1250 x 2000
x 1400 |
|
AVS300G |
Yes |
1 Auto |
Integral Generator |
3 ph Neutral-38A
28 kW* |
300 |
700 x 700 x
620 |
1250 x 2000
x 1400 |
|
AVS300D |
Yes |
1 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
300 |
700 x 700 x
620 |
1250 x 2000
x 1400 |
|
AVS350G |
Yes |
1 Auto |
Integral Generator |
3 ph Neutral-38A
28kW* |
350 |
700 x 700 x
725 |
1250 x 2000
x 1400 |
|
AVS350D |
Yes |
1 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
350 |
700 x 700 x
725 |
1250 x 2000
x 1400 |
|
AVS490G |
Yes |
1 Auto |
Integral Generator |
3 ph Neutral-70A
50kW* |
490 |
700 x 700 x
1000 |
1500 x 2000
x 1700 |
|
AVS490D |
Yes |
1 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
490 |
700 x 700 x
1000 |
1250 x 2000
x 1700 |
|
|
|
AVD216D |
Yes |
2 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
216 |
600 x 600 x
600 |
1500 x 2000
x 1000 |
|
AVD300D |
Yes |
2 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
300 |
700 x 700 x
620 |
1500 x 2000
x 950 |
|
AVD350G |
Yes |
2 Auto |
Integral Generator |
3 ph Neutral-70A
50kW* |
350 |
700 x 700 x
725 |
1500 x 2000
x 1300 |
|
AVD350D |
Yes |
2 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
350 |
700 x 700 x
725 |
1500 x 2000
x 1050 |
|
AVD490G |
Yes |
2 Auto |
Integral Generator |
3 ph Neutral-70A
50kW* |
490 |
700 x 700 x
1000 |
1500 x 2000
x 1300 |
|
AVD490D |
Yes |
2 Auto |
Direct Steam |
3 ph Neutral-6A
4kW |
490 |
700 x 700 x
1000 |
1500 x 2000
x 1300 |
* Some applications
may require a larger steam generator, therefore these values could
increase. |